• 2/4p RCCB 16A-63A Residual Current Circuit Breaker
  • 2/4p RCCB 16A-63A Residual Current Circuit Breaker
  • 2/4p RCCB 16A-63A Residual Current Circuit Breaker
  • 2/4p RCCB 16A-63A Residual Current Circuit Breaker
  • 2/4p RCCB 16A-63A Residual Current Circuit Breaker
  • 2/4p RCCB 16A-63A Residual Current Circuit Breaker

2/4p RCCB 16A-63A Residual Current Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • About Us
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RCCB-63
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CCC
MOQ
1 Piece
Delivery Time
7 Days~30 Days
Pole
2p/4p
OEM ODM
OEM ODM
Rated Voltage
400V
Rated Current
16,20,25,32,40,50,63A
Certificate
CCC, CE, ISO
Transport Package
Carton/Pallet
Specification
1.2*0.8m
Trademark
Custom
Origin
China
HS Code
853620000
Production Capacity
1000

Product Description

Product Description

 

Product Name  2/4P RCCB 16A-63A residual current circuit breaker
Rated Frequency (Hz) 50/60HZ
Poles Number 1P/2P/3P/4P/1P+N/3P+N
Rated Current 16,20,25,32,40,50,63A
Rated Voltage 230V
Detailed Photos
 
2/4p RCCB 16A-63A Residual Current Circuit Breaker
2/4p RCCB 16A-63A Residual Current Circuit Breaker

 

  
Product Parameters
 

 

1 Type 4P Residual Current Circuit Breaker
2 Model Number CJL2-100
3 Rated current 16,20,25,32,40,50,63A
4 Rated Voltage AC 230V/415V
5 Rated Frequency (Hz) 50/60Hz
6 Breaking Capacity 6KA
7 Certificate CCC, CE, ISO
8 Supply Ability 300000 Piece/Pieces per Month
 

Features
 

 

·Earth Faults (Ground Faults): These occur when current leaks from the live conductor to the earth due to insulation damage or contact with conductive surfaces. RCCBs can quickly detect and disconnect the circuit in such cases, preventing electric shocks. 
 

·Residual Currents: These happen when there's an imbalance between the live and neutral currents, often caused by faulty appliances or wiring. RCCBs can detect even small residual currents, minimizing the risk of electric shock.

 

 

2/4p RCCB 16A-63A Residual Current Circuit Breaker
   
About Us

 

2/4p RCCB 16A-63A Residual Current Circuit Breaker
  
We founded in 2013, the mother factory is Jialing Electric Co.,Ltd as one of professional manufactures in electrical manufacturing industry over 23 years, total area around 10000m². 
We are an integrated industrial & trading enterprise for design, production, sales and customized service. It is specialized in developing and manufacturing each metal parts of Air Circuit Breaker, Earth Leakage Circuit Breaker and Electronic Mould Case Circuit Breaker series, and then assembled finished products.
 
Since its inception, we comply with quality policy "technical innovation makes quality better, quality system makes quality steady, high grade service makes quality realistic". 
With important process into the production of intelligent devices, implement quality management strictly according to ISO9001 standards and experienced technical team development projects, to ensure supply high and stable quality products then gained acceptance in the domestic market. 
 
Our products are widely used in petroleum, chemical, power, building, machinery and metallurgical industry. Provide the professional and efficient customized service with our strong R&D capability, technical support capability and mold manufacturing capabilities. To be interdependent, mutual benefit and win-win friendly partners. 
 
Tenet of the company is Better competitive, Better lead time, Better service.
 
2/4p RCCB 16A-63A Residual Current Circuit Breaker
 
Certifications

 

2/4p RCCB 16A-63A Residual Current Circuit Breaker
 
FAQ

 

Q1. What is your terms of packing?
A: Goods pack with separate box and carton.
we can pack the goods in your branded boxes after getting your authorization if you need.
 
Q2. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before we received the balance.
 
Q3. How about your delivery time?
A: It will take 5 days to 10 days after received your advance payment. 
The specific delivery time depends on the items and the quantity of your order, normally lead time within 30 days.
 
Q4. Can you produce according to the samples?
A: We can design and produce the goods according to your samples or technical drawings. 
 
Q5. What is your sample policy?
A: We can supply the sample if we have ready parts in stock.
But the customers have to pay the sample cost and  the cost of freight.
 
Q6. Do you test all your goods before delivery?
A: Of course, we have 100% test before delivery.

Any more questions please contact us, thank you.

 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
120
Year of Establishment
2013-01-29